DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-185

                                                           (s)    Use a multimeter to measure the resistance
                                                                  between the pin 2 of main fan connector A012
                                                                  and the ground.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin                                           04
                                                               A012(2)- ground                > 10 MΩ












                                                           (t)    Use a multimeter to measure the resistance
                                                                  between the pin 1 of auxiliary fan connector
                                                                  A013 and the ground.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin

                                                               A013(1)- ground                > 10 MΩ











                                                           (u)    Use a multimeter to measure the resistance
                                                                  between the pin 3 of main fan connector A012
                                                                  and the ground.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin

                                                               A012(3)- ground                  <10 Ω