04-262                     DIAGNOSTICS - ENGINE CONTROL SYSTEM


           (d)    Confirm whether there is fault code related to EGR valve position circuit?

           Is the inspection result normal?
           YES>To step 2.

           NO>Intermittent trouble exists.
      04
           2 .    Check EGR valve position circuit
           (a)    Ignition switch: OFF.
           (b)    Disconnect the battery negative cable.
           (c)    Disconnect the EGR valve connector E18.
           (d)    Connect the battery negative cable.
           (e)    Ignition switch: ON.

                                                      (f)    Use a multimeter to measure the voltage
                                                             between the pin 5 of EGR valve connector
                                                             E18 and the ground.

                                                             Standard voltage

                                                       Multimeter connection          Standard value
                                                                 pin

                                                          E18(5)-ground                4.75~5.25 V











           Is the inspection result normal?

           YES>To step 3.
           No > Maintain or replace the harness.

           3 .    Check EGR valve harness

           (a)    Ignition switch: OFF.
           (b)    Disconnect the battery negative cable.
           (c)    Disconnect the EGR valve connector E18.
           (d)    Disconnect connector E01 of ECM.