Page 408 - Foton Workshop Manual - Tunland (AT)
P. 408
04-262 DIAGNOSTICS - ENGINE CONTROL SYSTEM
(d) Confirm whether there is fault code related to EGR valve position circuit?
Is the inspection result normal?
YES>To step 2.
NO>Intermittent trouble exists.
04
2 . Check EGR valve position circuit
(a) Ignition switch: OFF.
(b) Disconnect the battery negative cable.
(c) Disconnect the EGR valve connector E18.
(d) Connect the battery negative cable.
(e) Ignition switch: ON.
(f) Use a multimeter to measure the voltage
between the pin 5 of EGR valve connector
E18 and the ground.
Standard voltage
Multimeter connection Standard value
pin
E18(5)-ground 4.75~5.25 V
Is the inspection result normal?
YES>To step 3.
No > Maintain or replace the harness.
3 . Check EGR valve harness
(a) Ignition switch: OFF.
(b) Disconnect the battery negative cable.
(c) Disconnect the EGR valve connector E18.
(d) Disconnect connector E01 of ECM.
Page 408