DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-273

                                                           (f)    Use a multimeter to measure the resistance
                                                                  between the pin 2, 3 of the DPF temperature
                                                                  sensor connector Q01 and the pin 15, 16 of
                                                                  ECM connector E01 respectively.

                                                                  Standard resistance

                                                            Multimeter connection                                    04
                                                                                           Standard value
                                                                       pin
                                                             Q01(2)- E01(15)                    <10 Ω

                                                             Q01(3)- E01(16)                    <10 Ω







                                                           (g)    Use a multimeter to measure the resistance
                                                                  between the pin 2, 3 of DPF temperature
                                                                  sensor connector Q01 and the ground.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin

                                                               Q01(2)- ground                  >10 MΩ

                                                               Q01(3)- ground                  >10 MΩ








                 Is the inspection result normal?
                 YES>To step 5.

                 No > Maintain or replace the harness.

                 5 .    Replace DPF temperature sensor
                 (a)    Replace DPF temperature sensor
                 (b)    Use a diagnostic apparatus to perform DTC verification procedures.
                 (c)    Implement the steps to read sensor data stream.
                 (d)    Check whether DTC exists.

                 Is the inspection result normal?
                 YES>Replace DPF temperature sensor

                 NO >To step 6.

                 6 .    Replace ECM
                 (a)    Replace ECM.
                 (b)    Use a diagnostic apparatus to perform DTC verification procedures.
                 (c)    Implement the steps to read sensor data stream.