DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-471

                 EXCESSIVE OIL CONSUMPTION


                      Fault phenomenon                  Diagnosis logic                Possible reasons
                                                                                  • Oil filter leakage
                                                  • Engine oil filter
                                                                                  • Lubrication system fault
                                                  • Lubrication system
                                                                                  • Oil condenser fault
                                                  • Oil condenser                                                    04
                                                                                  • Crankcase ventilation
                                                  • Crankcase ventilation
                                                                                    system fault
                                                    system
                                                                                  • Turbocharger fault
                  Excessive oil consumption       • Turbocharger                  • Valve oil seal fault
                                                  • Valve oil seal
                                                                                  • Piston ring fault
                                                  • Valve guide pipe
                                                                                  • Valve guide pipe fault
                                                  • Piston ring
                                                                                  • Too long oil maintenance
                                                  • Oil maintenance period
                                                                                    period
                                                  • Engine oil
                                                                                  • Poor engine oil quality

                 Diagnosis Procedure

                 1 .    Check the engine data

                 (a)    Ignition switch: OFF.
                 (b)    Connect the diagnosis tool with the fault diagnosis connector (16 pins) on the lower
                        left of the dashboard.
                 (c)    Ignition switch: ON, and start the diagnostic tool.
                 (d)    Read the motor data shown on the diagnostic tool.

                 Check whether the data flow is normal or not.
                 YES>To step 2.
                 No >Maintenance related faults.


                 2 .    Check engine oil
                 (a)    Check the quality of engine oil is accord with standard.

                 Is the inspection result normal?
                 YES>To step 3.
                 NO> Replace new oil.


                 3 .    Check oil maintenance period
                 (a)    Check whether engine oil maintenance period is accord with the standard.

                 Is the inspection result normal?
                 YES>To step 4.
                 NO>Replace engine oil.


                 4 .    Oil condenser
                 (a)    Check whether the engine oil filter leaks.
                 Is the inspection result normal?