Page 649 - Foton Workshop Manual - Tunland (AT)
P. 649

DIAGNOSTICS - SRS SYSTEM                              04-503

                 Diagnostic steps

                 1 .    Check harness (SRS control module-lock spring)

                 (a)    Confirm the ignition switch is closed, and disconnect the negative pole of the battery
                        for more than 90 seconds.


                                                           (b)    Disconnect the connector of lock spring C010.   04



















                                                           (c)    Disconnect SRS control module connector
                                                                  C016.






















                                                           (d)    Measure the electrical resistance between
                                                                  SRS control module connector C016 and the
                                                                  ground based on the value in the following
                                                                  form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value

                                                                C016 (6) ground                 < 2 Ω









                 Check whether the result is normal?