Page 649 - Foton Workshop Manual - Tunland (AT)
P. 649
DIAGNOSTICS - SRS SYSTEM 04-503
Diagnostic steps
1 . Check harness (SRS control module-lock spring)
(a) Confirm the ignition switch is closed, and disconnect the negative pole of the battery
for more than 90 seconds.
(b) Disconnect the connector of lock spring C010. 04
(c) Disconnect SRS control module connector
C016.
(d) Measure the electrical resistance between
SRS control module connector C016 and the
ground based on the value in the following
form.
Standard electrical resistance (check
whether there existent an open circuit)
Multimeter connection Standard value
C016 (6) ground < 2 Ω
Check whether the result is normal?
Page 649