DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM                       04-719

                                                           (a)    Use master control switch to unlock the door,
                                                                  meanwhile use multimeter to measure the
                                                                  voltage between stitch 4 of connector G006
                                                                  of the right front lock motor and the ground.

                                                                  Standard voltage

                                                            Multimeter connection          Standard value            04
                                                                                            Battery voltage

                                                                G006(4)-ground          (Lasts about 0.3 ~ 1.1
                                                                                                   s)








                 Check whether the result is normal?
                 Yes> replace lock motor, right front door
                 No> Repair the open circuit between stitch 4 of connector G006 of the lock motor,
                 right front door and stitch B3 of connector C033 of the body controller.