DIAGNOSTICS - WIPER & WASHER                             04-743

                                                           (c)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard resistance (check whether there
                                                                  is an open circuit)
                                              C012
                     1  2  3  4  5  6  7  8  9  10
                                                            Multimeter connection          Standard value
                                                                                                                     04
                                                               C012 (8) - ground                < 2 Ω









                                                 ftwxd041503


                 Check whether the result is normal?
                 Yes> go to step 6
                 No > Maintenance or replace harness.


                 6 .    Check the harness and connectors (combination switch - BCM control unit)
                 (a)    Ignition Switch: OFF.

                                                           (b)    Disconnect the connector C012 of
                                                                  combination switch (wiper).














                                                 ftwx641020

                                                           (c)    Disconnect connector C035 of BCM control
                                                                  unit.














                                                 ftwxd041025