P. 919

DIAGNOSTICS - AIR CONDITIONING SYSTEM                        04-773


                 (a)    Disconnect battery negative cable.
                 (b)    Unplug the blower relay R03.

                                                           (c)    Check the blower relay R03.

                                                                  Standard resistance:
                                                                                                                     04
                                                                                Multimeter
                                                                                                   Specified
                                                              Conditions        connection
                                                                                                     value
                                                                                   stitch
                                                                Normal
                                                                situation         85–86            Breakover

                                                              Apply power
                                                             supply voltage
                                                               to position        30–87              <2Ω
                                                             between stitch
                                                               85 and 86,



                 Check whether the result is normal?
                 Yes> go to step 4

                 No > Replace the blower relay, and verify again whether the failure exists.

                 4 .    Check the harness and connectors (blower relay – blower motor)
                 (a)    Disconnect battery negative cable.

                                                           (b)    Disconnect the connector C025 of blower.
                                                           (c)    Unplug the blower relay R03.










































                                                                                                         Page 919
   914   915   916   917   918   919   920   921   922   923   924