04-780                     DIAGNOSTICS - AIR CONDITIONING SYSTEM


           (a)    Disconnect battery negative cable.
           (b)    Unplug the relay R4 of starter.

                                                      (f)    Measure the voltage based on the value in
                                                             the following form.

      04                                                     Standard voltage
                                                       Multimeter connection          Standard value

                                                         R04(1)- ground                    < 2Ω















           Check whether the result is normal?
           Yes> go to step 4

           No > Maintenance or replace harness.

           4 .    Check the relay of air conditioner compressor
           (a)    Disconnect battery negative cable.
           (b)    Unplug the relay R14 of air conditioner compressor

                                                      (c)    Check the relay of air conditioner compressor.

                                                             Standard resistance:

                                                                           Multimeter
                                                                                             Specified
                                                        Conditions        connection            value
                                                                             stitch

                                                           Normal
                                                          situation            1-2           Breakover

                                                        Apply power
                                                       supply voltage
                                                         to position           3-5              <2Ω
                                                       between stitch
                                                          3 and 5,



           Check whether the result is normal?
           Yes> go to step 5

           No > Replace the relay of air conditioner compressor, and verify again whether the
           failure exists.

           5 .    Check the harness and connectors (relay of air conditioner compressor - ground)