Page 2197 - Foton Workshop Manual - Sauvana
P. 2197

DIAGNOSIS-POWER DOOR LOCK                                62-145

                 Is the result normal?
                 Yes>To step3.
                 No >Maintain the short circuit to ground both of the locking control circuit and the unlocking
                         control circuit of the central lock.


                 3.     Check the control circuit of the driver door lock                                           62


                                                            (a).   Disconnect the connector C58 of the body
                                                                   controller.





















                                                 fuwx62303

                                                            (b).   Measure  the  resistance  between  the
                                                                   grounding and the No.E30 pin of the
                                                                   connector C58 on the body controller with
                                                                   the multimeter.
                                                                   Standard resistance: (check whether there
                                                                   is a short circuit)

                                                                                       Connect by      Standard
                                                                      Conditions
                                                                                       multimeter       value
                                                                        The lock
                                                                         state          C58 (E30) -
                                                                       feedback         Grounding        ≤ 2 Ω
                                                                     switch is OFF

                                                                        The lock
                                                                         state          C58 (E30) -
                                                                       feedback         Grounding       Infinite
                                                                     switch is ON.

                 Is the result normal?
                 Yes>Find the causes from other symptoms.
                 No >Maintain the open circuit to ground of the control circuit on the driver door lock.








                                                                                                     Page 2197
   2192   2193   2194   2195   2196   2197   2198   2199   2200   2201   2202