Page 2361 - Foton Workshop Manual - Sauvana
P. 2361

DIAGNOSIS-LIGHTING SYSTEM                               62-309

                                                            (d).   Turning the combination switch to the
                                                                   "dipped  headlight"  gear,  measure  the
                                                                   voltage  between  the  No.2  terminal  of
                                                                   connector A28 and A03 on the left and right
                                                                   front combination lamp and the grounding
                                                                   with the multimeter.                             62
                                                                   Standard resistance: (check whether there
                                                                   is a short circuit)

                                                                         Connect by          Standard value
                                                                         multimeter
                                                                      A28(2) - Grounding        Battery volt

                                                                      A03(2) - Grounding        Battery volt

                 Is the inspection result normal?
                 Yes>To step 5.
                 No >Maintain the disconnection of harness between the connector A28 of the left front
                        combination lamp and the left dipped fuse, and between the connector A03 of the right
                        front combination and the right dipped fuse.


                 5.     Check harness short circuit to the grounding


                 (a).   Ignition switch:"LOCK".
                 (b).   Disconnect the left front combination lamp connector A28.
                 (c).    Disconnect the right front combination lamp connector A03.


                                                            (d).   Measure the resistance between the No.2
                                                                   terminal of the left front combination
                                                                   lamp connector A28 and also the No.2
                                                                   terminal of the right front combination lamp
                                                                   connector A03 and the grounding with a
                                                                   multimeter.
                                                                   Standard resistance: (check whether there
                                                                   is a short circuit)

                                                                     Connect the pin by      Standard value
                                                                         multimeter

                                                                      A28(2) - Grounding         > 1 MΩ
                                                                      A03(2) - Grounding         > 1 MΩ

                 Is the inspection result normal?
                 Yes>To step 6.
                 No >Maintain the disconnection of harness between the connector A28 of the left front
                        combination lamp and the left dipped fuse, and between the connector A03 of the right
                        front combination and the right dipped fuse.



                                                                                                     Page 2361