Page 746 - Foton Workshop Manual - Sauvana
P. 746
16A-4 COOLING - COOLING SYSTEM
(c). Disconnect the electronic fan connector.
fuwx16A004
(d). Test the electronic fan with battery, current
meter and wires.
"1" refers to the negative pole of the
battery. "2" refers to the positive pole of the
battery in the serial connected with a curren
connected with a t meter. "3" refers to the
negative pole of the main electronic fan. "4"
refers to the low-speed level of the master
electronic fan. "5" refers to the high-speed
level of the master electronic fan. "6" refers
to the negative pole of the supplementary
electronic fan. And "7" refers to the high-
speed level of the supplementary electronic
fuwx16A005
fan.
• Connect "1" to "3" and "2" to "4". Now the
master electronic fan runs in low speed
and the current meter shows ≤ 10A.
• Connect "1" to "3" and "2" to "5". Now the
master electronic fan runs in high speed
and the current meter shows ≤ 17A.
• Connect "1" to "6" and "2" to "7". Now the
supplementary electronic fan runs
in high speed and the current meter
shows ≤ 19A.
(e). Plug the electronic fan connector back to
its place.
(f). Restore the engine hood.
fuwx16A004
Page 746