Page 765 - Foton Workshop Manual - Sauvana
P. 765

COOLING - COOLING SYSTEM                                16C-5

                                                            (c).   Disconnect the electronic fan connector.
















                                                fuwx16C004


                                                            (d).   Test the electronic fan with battery, current
                                                                   meter and wires.
                                                                   "1" refers to the  negative  pole  of the
                                                                   battery. "2" refers to the positive pole of the
                                                                   battery in the serial connected with a curren
                                                                   connected with a t meter. "3" refers to the      16C
                                                                   negative pole of the main electronic fan. "4"
                                                                   refers to the low-speed level of the master
                                                                   electronic fan. "5" refers to the high-speed
                                                                   level of the master electronic fan. "6" refers
                                                                   to the negative pole of the supplementary
                                                                   electronic fan. And "7" refers to the high-
                                                                   speed level of the supplementary electronic
                                                fuwx16C005
                                                                   fan.
                                                                    • Connect "1" to "3" and "2" to "4". Now the
                                                                      master electronic fan runs in low speed
                                                                      and the current meter shows ≤ 10A.
                                                                    • Connect "1" to "3" and "2" to "5". Now the
                                                                      master electronic fan runs in high speed
                                                                      and the current meter shows ≤ 17A.
                                                                    • Connect "1" to "6" and "2" to "7". Now the
                                                                      supplementary electronic fan runs
                                                                      in high speed and the current meter
                                                                      shows ≤ 19A.
                                                            (e).   Plug the electronic fan connector back to
                                                                   its place.
                                                             (f).   Restore the engine hood.












                                                fuwx16C004

                                                                                                      Page 765
   760   761   762   763   764   765   766   767   768   769   770