04-408                     DIAGNOSTICS - ENGINE CONTROL SYSTEM

      04     THE VACUUM PUMP DOES NOT KEEP ENOUGH VACUUM


                 Fault phenomenon                  Diagnosis logic                Possible reasons
                                            • Vacuum system                 • Vacuum system fault
            The vacuum pump does not        • Vacuum pump                   • Vacuum pump fault
            keep enough vacuum
                                            • Vacuum booster                • Vacuum booster fault


           Diagnosis Procedure

           1 .    Check the engine data
           (a)    Ignition switch: OFF.
           (b)    Connect the diagnosis tool with the fault diagnosis connector (16 pins) on the lower
                  left of the dashboard.
           (c)    Ignition switch: ON, and start the diagnostic tool.
           (d)    Read the motor data shown on the diagnostic tool.

           Check whether the data flow is normal or not.
           YES>To step 2.

           No >Maintenance related faults.

           2 .    Check vacuum pump
           (a)    Check whether vacuum pump is damaged or not.

           Is the inspection result normal?
           YES>To step 3.
           NO>Replace the vacuum pump.


           3 .    Check vacuum booster
           (a)    Check whether the vacuum booster leaks.
           Is the inspection result normal?

           YES>To step 4.
           NO>Replace the vacuum booster.


           4 .    Check vacuum system
           (a)    Check whether the vacuum system leaks.
           (b)    Check whether the vacuum pipeline has phenomenon of aging, cracking and so on.
           Is the inspection result normal?

           YES>Complete the diagnosis and the system is confirmed to be normal.
           No >Maintenance related faults.