Page 1104 - Workshop Manual - Tunland (2017)
P. 1104

04-418                     DIAGNOSTICS - ENGINE CONTROL SYSTEM

      04     EXCESSIVE VIBRATION


                 Fault phenomenon                  Diagnosis logic                Possible reasons
                                            • Exterior, interior or support  • Exterior, interior or support
                                              of an engine                    of an engine fault
            Excessive vibration             • Engine suspension             • Engine suspension fault
                                            • Body                          • Body fault
                                            • Chassis                       • Chassis fault


           Diagnosis Procedure

           1 .    Check the engine data
           (a)    Ignition switch: OFF.
           (b)    Connect the diagnosis tool with the fault diagnosis connector (16 pins) on the lower
                  left of the dashboard.
           (c)    Ignition switch: ON, and start the diagnostic tool.
           (d)    Read the motor data shown on the diagnostic tool.
           Check whether the data flow is normal or not.

           YES>To step 2.
           No >Maintenance related faults.

           2 .    Check the engine suspension

           (a)    Check whether there is resonance between the engine and the chassis or the body.
           (b)    Check if the cushion in the engine suspension is aging or cracked.
           Is the inspection result normal?

           YES>To step 3.
           No >Maintenance related faults.

           3 .    Check engine external parts

           (a)    Check whether the external components of the engine are properly assembled.
           Is the inspection result normal?
           YES>To step 4.

           No >Maintenance related faults.

           4 .    Check engine internal parts
           (a)    Check whether the internal parts of the engine are worn or damaged.

           Is the inspection result normal?

           YES>Complete the diagnosis and the system is confirmed to be normal.
           No >Maintenance related faults.
   1099   1100   1101   1102   1103   1104   1105   1106   1107   1108   1109