Page 180 - Workshop Manual - Tunland (2017)
P. 180

04-42                             DIAGNOSTICS - SRS SYSTEM

           Diagnostic steps

           1 .    Check harness (SRS control module-lock spring)

           (a)    Confirm the ignition switch is closed, and disconnect the negative pole of the battery
                  for more than 90 seconds.


      04                                              (b)    Disconnect the connector of lock spring C010.



















                                                      (c)    Disconnect SRS control module connector
                                                             C016.






















                                                      (d)    Measure the electrical resistance between
                                                             SRS control module connector C016 and the
                                                             ground based on the value in the following
                                                             form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value

                                                          C016 (6) ground                 < 2 Ω









           Check whether the result is normal?
           Yes> go to step 2