Page 2036 - Workshop Manual - Tunland (2017)
P. 2036

61-30                      HEATER AND AIR CONDITIONING - A/C PIPE

                                                      (c)    Install the pipe between the expansion valve
                                                             and the compressor.



      61












                                                      (d)    Tighten the pipe retaining bolts connected to
                                                             the compressor.
                                                             Torque: 21 ~ 25N•m















                                                      (e)    Tighten the pipe retaining bolts.

                                                             Torque: 8 ~ 9 N·m






















                                                      6 .    Install the A/C High Pressure Pipe
                                                      (a)    Install the pipe between the expansion valve
                                                             and the pressure switch.