DIAGNOSTICS - POWER WINDOW 04-159
(b) Pull out Power window switch connector J004,
driver’s door
04
(d) Measure the electrical resistance between
power window switch connector J004(11)
in driver’s door and the ground.
Standard resistance (check whether there
is an open circuit)
Multimeter connection Standard value
J040 (11)- ground < 2 Ω
Check whether the result is normal?
Yes> Replace power window switch, driver’s door.
No > Maintenance or replace harness.
5 . Check harness and connector (power window motor, driver’s door-BCM control
unit)
(a) Ignition Switch: OFF.