DIAGNOSTICS - POWER WINDOW                              04-159

                                                           (b)    Pull out Power window switch connector J004,
                                                                  driver’s door







                                                                                                                     04














                                                           (d)    Measure the electrical resistance between
                                                                  power window switch connector J004(11)

                                                                  in driver’s door and the ground.
                                                                  Standard resistance (check whether there
                                                                  is an open circuit)

                                                            Multimeter connection          Standard value

                                                               J040 (11)- ground                < 2 Ω










                 Check whether the result is normal?

                 Yes> Replace power window switch, driver’s door.
                 No > Maintenance or replace harness.

                 5 .    Check harness and connector (power window motor, driver’s door-BCM control
                        unit)

                 (a)    Ignition Switch: OFF.