04-428                         DIAGNOSTICS - LIGHTING SYSTEM

           Check whether the result is normal?

           Yes> go to step 6
           No > Maintenance or replace harness.

           6 .    Check the wiring harness and connectors (BCM controlling unit - combination
                  switch)
      04
           (a)    Ignition Switch: OFF.

                                                      (b)    Disconnect the connector C008 of
                                                             combination switch (lamplight switchover).














                                           ftwx641019


                                                      (c)    Disconnect the connector C036 of BCM
                                                             control unit.















                                           ftwxd041026

                                                      (d)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard resistance (Check for any open
                                                             circuit)

                                                       Multimeter connection          Standard value
                  16  15  14 13  12  11 10  9  8 7  6 5  4  3 2  1  C036
                  32  31  30  29  28  27  26  25  24  23  22  21  20 19  18  17
                                                         C036(E5)-C008                    < 2 Ω
                                                               (11)

               10  9  8  7  6  5  4  3  2  1  C008
               20  19  18  17  16  15  14 13 12  11



                                           ftwxd041011

           Check whether the result is normal?

           Yes> go to step 7