Page 592 - Workshop Manual - Tunland (2017)
P. 592

04-454                         DIAGNOSTICS - LIGHTING SYSTEM

                                                      (d)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value
      04          16  15  14 13  12  11 10  9  8 7  6 5  4  3 2  1  C036
                  32  31  30  29  28  27  26  25  24  23  22  21  20 19  18  17
                                                         C036(E5)-C008                    < 2 Ω
                                                               (11)

               10  9  8  7  6  5  4  3  2  1  C008
               20  19  18  17  16  15  14 13 12  11



                                           ftwxd041011


           Check whether the result is normal?
           Yes> go to step 4
           No > Maintenance or replace harness.


           4 .    Check the harness and connectors (combination switch (turn) - ground)
           (a)    Disconnect battery negative cable.

                                                      (b)    Disconnect the connector C008 of
                                                             combination switch (turn).














                                           ftwx641019

                                                      (c)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard resistance (check whether there
                                                             is short circuit)

                                            C008
                                                       Ground of multimeter           Standard value
                                                         C008 (19) - ground               < 2 Ω










                                           ftwxd041390
   587   588   589   590   591   592   593   594   595   596   597