Page 603 - Workshop Manual - Tunland (2017)
P. 603

DIAGNOSTICS - LIGHTING SYSTEM                            04-465


                 6 .    Check the door control switch

                                                           (a)    Disconnect the door control switch connector.





                                                                                                                     04


















                                                           (b)    Check the door control switch
                                                                  Standard voltage

                                                                                Multimeter
                                                              Conditions        connection         Specified
                                                                                                     value
                                                                                   stitch
                                                              Door closed        1 - Ground          < 2 Ω

                                                             Door opened         1 - Ground          Cut-off










                 Check whether the result is normal?
                 Yes> replace body controller

                 No > Replace the door control switch.
   598   599   600   601   602   603   604   605   606   607   608