6 . Check the door control switch
(a) Disconnect the door control switch connector.
04
(b) Check the door control switch
Standard voltage
Multimeter
Conditions connection Specified
value
stitch
Door closed 1 - Ground < 2 Ω
Door opened 1 - Ground Cut-off
Check whether the result is normal?
Yes> replace body controller
No > Replace the door control switch.