Page 635 - Workshop Manual - Tunland (2017)
P. 635
DIAGNOSTICS - ASSEMBLY INSTRUMENT 04-497
(a) Disconnect assembly instrument C013
connector
04
ftwx831083
(b) Use multimeter to measure the resistance
between No.3 stitch of speed sensor K001
connector and ground.
Standard resistance (check whether there
is short circuit)
Multimeter connection Standard value
K001 (3) ground ≥ 1 MΩ
K001
ftwxd041424
(c) Use multimeter to measure the resistance
between No.3 stitch speed sensor K001
connector and No.25 stitch of C013
connector.
C013
Standard electrical resistance (check
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 whether there existent an open circuit)
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
Multimeter connection Standard value
25
K001 (3) - C013 (25) ≤ 2 Ω
K001
ftwxd041304