Page 651 - Workshop Manual - Tunland (2017)
P. 651
DIAGNOSTICS - ASSEMBLY INSTRUMENT 04-513
(b) Disconnect the connector of brake liquid level
alarm switch A009.
(c) Ignition Switch: ON.
04
Check whether the brake failure alarm lamp is off
No > Replace the brake liquid level alarm switch.
No> go to step 5
CAUTION
Brake liquid level alarm switch should not be replaced separately, instead, the oil
storage cup assembly is required to be replaced.
5 . Check the brake liquid level alarm switch signal circuit
(a) Use a multimeter to measure the voltage
between the pin 1 of the brake liquid level
ON
alarm switch and ground.
A009 Standard voltage
1 2 Multimeter connection Standard value
A009 (1) - grounding Battery voltage
ftwxd041316
Check whether the result is normal?
Yes> go to step 6
No> go to step 7