Page 683 - Workshop Manual - Tunland (2017)
P. 683
DIAGNOSTICS - TYRE PRESSURE MONITORING SYSTEM 04-545
(c) Use a multimeter to measure resistance
value.
Standard electrical resistance (check
whether there existent an open circuit)
Multimeter connection Standard value
04
Battery (+) -D005(1 < 2 Ω
D005
ftwxd041430
Check whether the result is normal?
Yes> go to step 3
No > Maintenance or replace harness.
3 . Check the harness and connector (tyre pressure monitoring controller
-grounding)
(a) Ignition Switch: OFF.
(b) Disconnect the connectorD005 of the tyre pressure monitoring controller.
(c) Use a multimeter to measure resistance
value.
Standard electrical resistance (check
whether there existent an open circuit)
Multimeter connection Standard value
D005
D005(16)- grounding < 2 Ω
ftwxd041431
Check whether the result is normal?
Yes> go to step 4
No > Maintenance or replace harness.
4 . Check harness and connector (ignition switch -tyre pressure monitoring
controller)
(a) Ignition Switch: OFF.
(b) Disconnect the connectorD005 of the tyre pressure monitoring controller.