Page 916 - Workshop Manual - Tunland (2017)
P. 916
04-230 DIAGNOSTICS - ENGINE CONTROL SYSTEM
04 (e) Use a multimeter to measure the resistance
between the pin1 of DPF temperature sensor
connector Q01 and the ground.
Standard resistance
Multimeter connection
Standard value
pin
Q01(1)- ground <10 Ω
(f) Use a multimeter to measure the resistance
between the pin 2, 3 of the DPF temperature
sensor connector Q01 and the pin 15, 16 of
ECM connector E01 respectively.
Standard resistance
Multimeter connection
Standard value
pin
Q01(2)- E01(15) <10 Ω
Q01(3)- E01(16) <10 Ω
(g) Use a multimeter to measure the resistance
between the pin 2, 3 of DPF temperature
sensor connector Q01 and the ground.
Standard resistance
Multimeter connection
Standard value
pin
Q01(2)- ground >10 MΩ
Q01(3)- ground >10 MΩ
Is the inspection result normal?
YES>To step 5.
No > Maintain or replace the harness.