Page 916 - Workshop Manual - Tunland (2017)
P. 916

04-230                     DIAGNOSTICS - ENGINE CONTROL SYSTEM

      04                                              (e)    Use a multimeter to measure the resistance
                                                             between the pin1 of DPF temperature sensor
                                                             connector Q01 and the ground.
                                                             Standard resistance

                                                       Multimeter connection
                                                                                      Standard value
                                                                 pin
                                                         Q01(1)- ground                   <10 Ω












                                                      (f)    Use a multimeter to measure the resistance
                                                             between the pin 2, 3 of the DPF temperature
                                                             sensor connector Q01 and the pin 15, 16 of
                                                             ECM connector E01 respectively.
                                                             Standard resistance

                                                       Multimeter connection
                                                                                      Standard value
                                                                 pin

                                                       Q01(2)- E01(15)                    <10 Ω
                                                       Q01(3)- E01(16)                    <10 Ω







                                                      (g)    Use a multimeter to measure the resistance
                                                             between the pin 2, 3 of DPF temperature
                                                             sensor connector Q01 and the ground.
                                                             Standard resistance

                                                       Multimeter connection
                                                                                      Standard value
                                                                 pin

                                                         Q01(2)- ground                  >10 MΩ
                                                         Q01(3)- ground                  >10 MΩ









           Is the inspection result normal?
           YES>To step 5.
           No > Maintain or replace the harness.
   911   912   913   914   915   916   917   918   919   920   921