Page 2 - Vægtlodder fra KERN
P. 2

KERN Pictograms


            Internal adjusting:              Piece counting:                   Suspended weighing:
            Quick setting up of the balance‘s     Reference quantities selectable.    Load support with hook on the underside
            accuracy with internal adjusting    Display can be switched from piece    of the balance.
            weight (motor driven).           to weight.

            Adjusting program CAL:           Recipe level A:                   Battery operation:
            For quick setting up of the balance‘s    Separate memory for the weight of    Ready for battery operation. The battery
            accuracy. External adjusting weight   the tare container and the recipe    type is specified for each device.
            required.                        ingredients (net total).

            Memory:                          Recipe level B:                   Rechargeable battery pack:
            Balance memory capacity, e.g.    Internal memory for complete recipes    Rechargeable set.
            for article data, weighing data,    with name and target value of the recipe
            tare weights, PLU etc.           ingredients. User guidance through
                                             display.
            Alibi memory:                    Recipe level C:                   Universal mains adapter: with universal
            Electronic archiving of weighing results,   Internal memory for complete recipes    input and optional input socket adapters for
       ALIBI  complying with the 2009/23/EC standard.   with name and target value of the recipe   MULTI  A) EU, GB
            For details see page 214         ingredients. User guidance through display,   B) EU, GB, CH, USA
                                             adjustment of recipe when dosages are   C) EU, GB, CH, USA, AUS
                                             exceeded, multiplier function, barcode.
            Data interface RS-232:                                             Mains adapter:
            To connect the balance to a printer,                               230V/50Hz in standard version for EU.
            PC or network.                                                     On request GB, USA or AUS version
                                                                               available.
            RS-485 data interface:           Totalising level A:               Power supply:
            To connect the balance to a printer, PC    The weights of similar items can     Integrated in balance. 230V/50Hz
            or other peripherals. High toler ance   be added together and the total    standard EU. More standards e.g.
            against electromagnetic disturbance.  can be printed out.          GB, USA or AUS on request.

            USB data interface:              Totalising level C:               Weighing principle: Strain gauges
            To connect the balance to a printer,    Internal memory for complete recipes   Electrical resistor on an elastic
            PC or other peripherals.         with name and target value of the recipe   deforming body.
                                             ingredients. User guidance through display,
                                             adjustment of recipe when dosages are
            Bluetooth* data interface:       exceeded, multiplier function, barcode   Weighing principle: Tuning fork
            To transfer data from the balance to    recognition.               A resonating body is electromagnetically
            a printer, PC or other peripherals.                                excited, causing it to oscillate.


            WLAN data interface:             Percentage determination:         Weighing principle: Electromagnetic
            To transfer data from the balance to    Determining the deviation in % from    force compensation
            a printer, PC or other peripherals.  the target value (100 %).     Coil inside a permanent magnet. For the
                                                                               most accurate weighings.

            Control outputs                  Weighing units:                   Weighing principle: Single cell
            (optocoupler, digital I/O):      Can be switched to e.g. nonmetric units    technology
            To connect relays, signal lamps,    at the touch of a key. See balance model.    Advanced version of the force compen-
            valves, etc.                     Please refer to KERN‘s website for more   sation principle with the highest level of
                                             details.                          precision.
            Interface for second balance:    Weighing with tolerance range:    Verification possible:
            For direct connection of a second    Upper and lower limiting values can    The time required for verification is
            balance.                         be pro grammed individually for e.g.    specified in the pictogram.
                                             dosing, sorting and portioning

            Network interface:               Hold function:                    DAkkS calibration possible (DKD):
            For connecting the scale to an Ethernet   (Animal weighing program) When the   The time required for DAkkS calibration is
            network. With KERN products you can    weighing conditions are un stable, a    shown in days in the pictogram.
            use a universal RS-232/LAN converter.   stable weight is calculated as an average
            See page 180                     value.
            Wireless data transfer:          Protection against dust and water   Package shipment:
            between the weighing unit and the    splashes IPxx:                The time required for internal shipping
            evaluation unit using an integrated    The type of protection is shown in the   preparations is shown in days in the
            radio module.                    pictogram. For details see the glossary.   pictogram.
                                             See page 72.
            GLP/ISO log:                     ATEX explosion protection:        Pallet shipment:
            The balance displays the weight,    Suitable for use in hazardous industrial   The time required for internal shipping
            date and time, regardless of a printer   environments, in which there is explosion   preparations is shown in days in the
            connection.                      danger. The ATEX marking is specified    pictogram.
                                             for each device.
            GLP/ISO log:                     Stainless steel:                  Warranty:
            With weight, date and time. Only with   The balance is protected against    The warranty period is shown in the
            KERN printers, see “Accessories”, see   corrosion.                 pictogram.
            page 177.
      * The Bluetooth ®  word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by KERN & SOHN GmbH is under
       license. Other trademarks and trade names are those of their respective owners.
   1   2   3   4   5   6   7