Page 21 - Catalogue 2016 - 17
P. 21

DIAGNOSTIC TESTS - LABORATORY



           DRUG TEST READER SYSTEM - FOR URINE DRUG CUPS/PANELS
       • 24570 DRUG READER - Italian software    DRUG 24574 24576 24577 24578 CUT OFF Detection                Suitable
       • 24571 DRUG READER - English software                             NG/ML  time                          in occu-
       • 24574 MULTI DRUG PANEL - 8 drugs        MTD    • •  • •  • •  • •  300  5-7 days                      pational
                                                 MDMA
                                                                           500
                                                                                5-7 days
       • 24576 MULTI DRUG CUP - 7 drugs + S.V.T.  MET   •    •    •    •   500  3-5 days                       medicine
                                                                                                               for cost
       • 24577 MULTI DRUG CUP - 8 drugs + S.V.T.  COC   • •  • •  • •  • •  300  2-5 days                      effective
                                                                                  -
                                                 THC
                                                                            50
       • 24578 MULTI DRUG CUP - 8 drugs + S.V.T.  AMP   • •   • •   • •   • •   500  2-5 days                  workers
                                                 MOP
                                                                                5-7 days
                                                                           300
       Simply scan one of the three multi drug test on   BUP  •   •         10  5-7 days                       screening
       drug reader and get a complete analysis at your PC.  BUP        •    5   5-7 days
       - automated analysis of “visual read” test panels  S.V.T.  •  •
                                                 OX
       - automatic test menu recognition (2D barcode)  S.G.  •    •
       - in-process system quality control check  PH         • •  • •
                                                 NiT
       - image capture, data management/export   Glut        •    •
       functionality, archived results           CRE         •    •
       - validated for use with multiple formats/test menus
       Main benefits:
       - automation - eliminates results interpretation
       variability/subjectivity
       - accurate, performance advantages vs. visual interpretation
       - speed - scanning process requires 15-30 sec.
       - flexible - multiple test formats/menu, semi-
       portable, simple installation, Windows compatible.                             24576           24574     24570
                                                      24576     24574       24577            24577
           MULTI DRUG “CUP” TEST                                  SALIVA DRUG TEST
       • 24546 MULTI DRUG “CUP” TEST - urine  Test panel is tightly fastened
                                         to the cup, protecting it from
       box of 25 tests for 7 drugs       contaminaiton
       Detects following parameters:
       (MTD/MDMA)+<COC>+<AMP500>+<MET500>                       24555
       +<THC>+<MOP>. For professional use.
       - easy to use - no urine handling, just
       insert the key into the active test and                                                         Collect oral fluid
       read results in 5 min.                                                                          with sponge
       - tightly sealed urine cup - no leaking or
       spilling of urine specimen
       - unique design - ensures that urine                  • 24555 MULTI DRUG SALIVA TEST
       used in the test, will be separated from              oral fluid (saliva) - box of 25 tests for 6 drugs
       residual urine, that will remain                      Multi drug tests provide accurate results in 10 min. for the
       uncontaminated, to be used for a                      following drugs: amphetamine, cocaine, marijuana cannabis,
       further test when necessary                           methamphetamine, opiates, phencyclidine.
       - key packed separately, ensures                      Cut-off levels meet SAMHSA standards.
       security that only the technician can   Temperature   For hospital and professional use.
       begin the test                  label
                                                             Multilanguage manual: GB, IT, FR, DE, ES, PT.
                      SCREENING TEST CUP - 24546                      ORAL FLUID SCREENING TEST DEVICE - 24555
            DRUG        CUT OFF NG/ML       DETECTION TIME*        DRUG        CUT OFF NG/ML        DETECTION TIME
            MOP               300               5-7 days           COC               20              10 min - 24 h
            COC               300               2-5 days           THC               30               up to 14 h
            THC               50                   -               AMP               50              10 min - 72 h
            AMP               500               2-5 days           MET               50              10 min - 72 h
            MDMA              500               5-7 days           PCP               10                  -
            MTD               300               5-7 days           OPI               40              1 h - more days
            MET               500               3-5 days
                                                                   MTD               45               up to 2 days
       * Drug use over detection time not measured
           DRUGS OF ABUSE, URINE TESTS FOR PROFESSIONAL USE
       • 24540 COCAINE TEST - strip - urine - cut-off: 300 ng/ml
       • 24541 MARIJUANA TEST - strip - urine - cut-off: 50 ng/ml  24540-41-42  24550            24551
       • 24542 OPIATES TEST - strip - urine - cut-off: 300 ng/ml
       Codes 24540-41-42 are sold in box of 50 strips
       individually packed in single pouch.
       • 24550 MULTI DRUG PANEL TESTS  urine
       box of 25 tests for 6 drugs
       • 24551 MULTI DRUG PANEL TESTS  urine
       box of 25 tests for 12 drugs
                                                                                                    SCREENING TEST CUP
       Multi drug tests provide accurate results in 10 min.                                      Drug        Cut off ng/ml    Detection time
       on the following drugs: amphetamine*, cocaine*,                                               24550  24551
                                                                                                      -
       marijuana cannabis*, methamphetamine*, opiates*,                                          MOP   300   300   5-7 days
                                                                                                 COC
                                                                                                             2-5 days
                                                                                                         300
                                                                                                          50
                                                                                                      50
       phencyclidine*, barbiturates, benzodiazepines, ecstasy,                                   THC   1000   1000    5-8 days
                                                                                                 AMP
                                                                                                             2-5 days
       morphine300, methadone, tricyclic antidepressants.                                        MDMA   -   500   5-7 days
                                                                                                      -
                                                                                                         300
       *Code 24550 contains tests for drugs with asterisk.                                       MTD   1000   1000    5-7 days
                                                                                                             3-5 days
                                                                                                 MET
       Cut-off levels meet SAMHSA standards.                                                      BZO     -   300   7-10 days
                                                                                                         300  2 days - 4 weeks
                                                                                                  BAR
                                                                                                        -
       All products are supplied with multilingual manual:                                        PCP     25   25
       English, Italian, French, Spanish, German, Portuguese.                                     OPI     2000   2000    5-7 days
                                                                                                               -
                                                                                                  TCA
                                                                                                        -
                                                                                                         1000
                                                                                                                12
   16   17   18   19   20   21   22   23   24   25   26