ECG, MONITORS & UL
ECG, MONITORS & ULTRASOUNDTRASOUND
SpO +NIBP+
2
ECG+TEMP GIMA VITAL SIGNS MONITORS
"Vital Signs" is a line of small multi-parameter patient monitors, which
SpO
2 can monitor the vital physiological parameters: non-invasive blood
pressure (NIBP), pulse oxygen saturation (SpO ), electrocardiogram
2
(ECG), temperature (TEMP) and capnography (EtCO ).
2
Features:
- small size, clear and bright display for remote view
35120
- up to 400 groups of NIBP measurements can be stored and listed
- up to 90 hours of EtCO , SpO and HR trend curve can be displayed
SpO + 2 2
2 - built-in rechargeable battery, optional built-in thermal printer
NIBP+ GIMA
TEMP code MONITOR SpO 2 NIBP ECG CO 2 TEMP
35120 VITAL-S •
35121 VITAL-SNT • • •
35121 35122 VITAL-SNET • • • •
35123 VITAL-C • •
*
35125 Printer - optional * Installation done by Gima if ordered with monitor.
SpO +
2 35141 Paper 5.1 cm x 12 m - box of 5 Need service if ordered later.
EtCO
2 35126 Lead acid re-chargeable battery - spare
35135 Adult SpO probe - spare 35120
2
35136 Pediatric SpO probe +
2
Optional 35137 ECG cable - spare Rail clamp 35128
35123 printer 35122 35140 NIBP cuff - 10-19 cm - pediatric
TECHNICAL SPECIFICATIONS 35142 NIBP cuff - 18-26 cm - pediatric XL
NIBP ECG and TEMP 35139 NIBP cuff - 25-35 cm - adult
Technology: Oscillometric method Heart rate range: 20bpm~300bpm
Standard measurement range: TEMP measurement range: 25°C~45°C 35143 NIBP cuff - 33-47 cm - adult XL
SystoIic: Adult: 50-240mmHg Accuracy: ±2bpm or 1% whichever is 35127 Trolley - adjustable 73 to 113 cm
Diastolic: Adult: 15-180mmHg greater (ECG) ±0.2°C (TEMP) 35128 Rail clamp
MAP: Adult: 25-200mmHg CO 2 STANDARD ACCESSORIES
Measurement mode: Manual, Auto, STAT Technology: Infrared absorption method 35120 35121 35122 35123
Sampling Mode: Sidestream or Mainstream
SpO 2 - Adult SpO probe • • • •
SpO 2 measurement range: 0%- 99% CO 2 Response Time: - Sidestream: <3seconds 2
SpO 2 measurement accuracy: 75%-99% ±2% (includes transport time and rise time) - NIBP adult cuff • •
50%-74% ±3% - Mainstream: <60ms (rise time) - Temperature probe - skin type • •
Low perfusion performance: 0.4% Power - ECG cable + 10 ECG electrodes •
Pulse rate measurement range: 30bpm~240bpm AC power supply voltage: 100~250V, 50/60Hz - Sidestream sensor and line kit •
Pulse rate measurement accuracy: International power supply: 12VDC (rechargeable) - Battery • • • • 35127
± 2bpm or 2% whichever is greater Battery specification: 12V 2,3AH (sealed lead-acid battery) - Manual (English) • • • •
UP 7000 MULTI-PARAMETER PATIENT MONITOR
GIMA
ECG+RESP+SpO + code ACCESSORIES AND SPARES
2
2 TEMP+PR 35135 Adult SpO probe
2
35136 Pediatric SpO probe
35137 ECG cable 2
35140 NIBP cuff - arm circumf. 10-19 cm - pediatric
31542 NIBP cuff - arm circumf. 18-26 cm - pediatric XL
35139 NIBP cuff - arm circumf. 25-35 cm - adult
31543 NIBP cuff - arm circumf. 33-47 cm - adult XL
35126 Lead acid rechargeable battery - spare 35150
35141 Paper 5.1 cm x 12 m - box of 5
35150 Trolley - adjustable 73 to 113 cm
STANDARD ACCESSORIES
- Adult SpO probe - Re-chargeable battery - Disposable electrode
2
- NIBP adult cuff - Printer - Dust-protective mantle
- Temperature probe - skin - Power supply cable - Manual (English, Italian)
- Temperature probe - rectal - ECG cable
TECHNICAL SPECIFICATIONS
NIBP Monitoring
Measuring method: Oscillometric
Measuring range: Systolic pressure: Diastolic pressure: Mean arterial pressure:
adult: 40~255mmHg 10~220mmHg 20~215mmHg
pediatric: 40~200mmHg 10~110mmHg 20~165mmHg
TEMP Monitoring
• 35145 MULTI-PARAMETER PATIENT MONITOR Measuring range: 25.0°C~45.0°C ±0.2°C
Response time:
≤ 150 sec
ECG, RESP, SpO , 2 TEMP, PR SpO & Pulse Rate Monitoring
2
2
- 12.1'' high resolution colour TFT display SpO measuring range: 35%~100%
2
30bpm~240bpm ±2bpm
PR measuring range:
- 3 channel ECG amplification ECG Monitoring
- arrhythmia analysis and ST segment analysis Heart rate measurement: ±0.4mVp~±5mVp
- up to 800 groups parameter data & 24-hour ECG waveform Heart rate display range: 20bpm~250bpm
storage and recall RESP Monitoring Thoracic impedance
Measuring method:
- 480-hour graphic and tabular trends for all parameters Monitoring range 0rpm~120rpm,
- 7 trace ECG waveforms simultaneous display Monitoring accuracy: ±5% or ±2rpm whichever is greater
- protection against interference from defibrillator Other Technical Specifications
100~250Vac, 50/60Hz
Power supply
- adult/pediatric measurement modes Power consumption: <80 VA
- visual and audible alarms Display mode 12.1 inches TFT color LCD
- built-in rechargeable battery Alarming mode Audible-visual alarm
Ethernet port
Networking port
- built-in thermal printer