1122  Inhalant Medication Administration


            occurs;  it  will  be  flagged  on  the  Holter    Postprocedure     •  Implantable  event  monitor  (Reveal  Plus,
            recording.                        After  the  recording  period  (24-48  hours  for   Medtronic): allows an extended period of
  VetBooks.ir  •  Animal preparation and patch preparation are   the bandage material, monitor, wires, and   very small (size of a USB jump drive), and
                                                                                   monitoring (up to 10 months). Devices are
           Event monitor:
                                              Holter; 6 days to 8 weeks for Event monitors),
                                                                                   implantation is achieved with a subcutane-
            the same as for Holter monitors (previously
                                              electrode patches are removed without the use
            described).
                                                                                   cases. Devices are donated to a veterinary
           •  There  are  only  two  wires/electrodes  and   of scissors. The entire system is unwrapped to   ous pocket and local anesthesia in many
                                              avoid cutting or damage to the leads and wires.
            therefore only two electrode patches (white   Removal of the skin patches can be facilitated   cardiology group (CanPacers) and are inex-
            electrode typically attached to electrode patch   with isopropyl alcohol. The cassette or digital   pensive. Access to a Medtronic programmer
            on right hemithorax).             card (or in some cases, the entire monitor) is   is necessary, however, to retrieve the stored
           •  The monitor is wrapped onto the animal as   returned to the supplier or sent away for analy-  information.
            described above. It is essential to leave the   sis. Some event monitor systems can transmit   •  Smartphone-based monitor for direct ECG
            record button visible and accessible.  the stored information transtelephonically to the   recording (www.alivecorvet.com): portable,
           •  When the animal has an episode, the owner   receiving station. If this is not done very soon   on-demand  ECG  recording,  good-quality
            must press the record button. Doing so   after a recorded event, however, the batteries   single-lead tracing, online storage of data; no
            captures the ECG preceding and after the   continue to be drained and the information   reachback effect, rhythm may have returned
            time the button was pressed. Typically, the   eventually will be lost. Be sure to collect the   to normal by the time owner applies the
            monitors are set to store the preceding   Holter diary from the owner as well so that   recorder
            45-second period of ECG and the subsequent   the recorded information can be interpreted in   •  Wireless, adhesive, waterproof, 14-day continu-
            15 seconds, for a total of 1 minute of ECG   relation to the patient’s activity level.  ous recorder patch (Zio Patch): investigational
            spanning the clinical episode.
           •  Event monitors typically have a total memory   Alternatives and Their    SUGGESTED READING
            of 5 minutes (i.e., five 1-minute episodes),   Relative Merits       Petrie JP: Practical application of Holter monitoring
            although newer models can store 18 minutes   •  In-hospital  ECG:  less  motion  artifact   in  dogs  and  cats.  Clin  Tech  Small  Anim  Pract
            or more.                            but shorter duration and under artificial   20:173-181, 2005.
           •  Newer  models  can  be  programmed  to   conditions                AUTHORS: Amara H. Estrada, DVM, DACVIM; Ashley
            automatically store events if the owner is   •  Holter monitor instead of event monitor:   E. Jones, DVM, DACVIM
            not present to witness the event. For example,   screening for occurrence of latent arrhythmia;   EDITORS: Leah A. Cohn, DVM, PhD, DACVIM; Mark S.
            the monitor can be programmed to record   antiarrhythmic drug monitoring  Thompson, DVM, DABVP
            any heart rate lower than 40 or higher than   •  Event monitor instead of Holter monitor:
            200 beats/min.                      long-term  (days)  monitoring;  smaller
           •  Typically, batteries must be changed every   animals;  transtelephonic  transmission  of
            5-7 days.                           recorded information









            Inhalant Medication Administration                                                      Bonus Material
                                                                                                         Online

                                              Contraindications
           Difficulty level: ♦                                                   •  Face  mask:  specific  to  size  and  shape  of
                                              •  Known hypersensitivity to the medication   animal’s muzzle; veterinary spacer devices
           Synonyms                             to be administered                 typically sold with a face mask
           Metered-dose inhaler (MDI), aerosol medica-  •  Facial  trauma/disfigurement  that  would
           tion, hydrofluoroalkane (HFA) inhaler  prevent placement of mask      Anticipated Time
                                              •  Frightened, agitated, stressed, or untrained   Well-trained  animal:  30-60  seconds  per
           Overview and Goal                    animal                           treatment
           The goal is to administer drugs directly to the
           airways to minimize systemic effects. Although   Equipment, Anesthesia  Preparation: Important
           most such medications are administered by   MDI can be used in hospital or by pet owners   Checkpoints
           MDI, other drugs can be administered through   at home. Although sedation is not necessary,   •  The majority of dogs and cats can tolerate
           nebulization. The drugs most often administered   training the pet to accept the mask and device   placement of the mask and spacer. Those
           by MDI in pets include glucocorticoids and   is often required.         that resist initially can usually (≈80% of
           bronchodilators.                   •  MDI containing drug of choice     cats, 95% of dogs) be trained to accept
                                                ○   Albuterol available as 90 mcg/actuation  treatments.
           Indications                          ○   Fluticasone  available  as  44,  110,  and   •  For a novice animal, expose it to the face
           Delivery of aerosolized medication directly to   220 mcg/actuation      mask  and  spacer/chamber  before  starting
           the upper and lower airways:       •  Spacer/chamber   device:   although   treatment with an MDI. Gradually introduce
           •  Rhinitis  (allergic  and  immune  mediated)    spacer devices made for humans can be   the mask with treats/peanut butter or butter
            (p. 890)                            adapted,  veterinary-specific  products  are     on the inside of the mask. Practice several
           •  Chronic bronchitis (p. 136)       preferred.                         times a day.
           •  Collapsing trachea (p. 194)       ○   Commercially available for dogs and cats   •  After the face mask is accepted, add on the
           •  Feline asthma (p. 84)               (https://www.trudellmed.com/animal-   spacer, holding the combination in place
           •  Other types of bronchopulmonary disease  health)                     initially for 5 seconds and building up to