Page 111 - A Practical Guide to Equine Radiography
P. 111

92  A PRACTICAL GUIDE TO EQUINE RADIOGRAPHY



                   Cranio 45º medial-caudolateral oblique          4.  Position the X-ray machine craniomedially
      VetBooks.ir  (Cr45M-CdLO) (Figs 9.9–9.12)                       to the limb at a 45-degree angle to the sagit-

                                                                      tal plane of the trunk.
                   1.  Position the horse as equally weight-bear-
                       ing as possible; this may be challenging in   5.  Focus–film distance: 100 cm.
                       horses with painful conditions.             6.  Use a horizontal X-ray beam.
                   2.  Place the plate in portrait orientation on   7.  Centre the X-ray beam on the elbow joint.
                       the caudolateral side of the joint, as close   8.  Collimate around the elbow.
                       as possible to the limb.                    9.  Exposure guide: 80 kVp, 20 mAs.
                   3.  Place a R/L marker on the lateral side of the
                       plate.



















































                   Figure 9.9  Positioning to obtain a Cr45M-CdLO view of the elbow.

























       Equine Radiography.indb   92                                                                              27/11/2018   11:09