146  A PRACTICAL GUIDE TO EQUINE RADIOGRAPHY



                   Ventrodorsal (VD) (Figs 14.16–14.18)            5.  Focus–film distance: 100 cm.
      VetBooks.ir  1.  Position the head with the nose extended    6.  Orientate the X-ray beam perpendicular to

                                                                      the plate.
                       rostrally as much as possible with the help
                       of a head stand. Avoid any tilting or rota-  7.  Centre the X-ray beam in the midline of the
                       tion of the head.                              head at the level of the temporomandibular
                   2.  Place the plate dorsal to the head aligned     joint.
                       with the nose/frontal region.               8.  Collimate around the head.
                   3.  Indicate right/left with a marker.          9.  Exposure guide: 90 kVp, 55 mAs.
                   4.  Position the X-ray machine ventral to the
                       head.






























































                   Figure 14.16  Positioning to obtain a VD view of the caudal aspect of the head.














       Equine Radiography.indb   146                                                                             27/11/2018   11:12