64  A PRACTICAL GUIDE TO EQUINE RADIOGRAPHY



                   Dorsopalmar (DPa) (Figs 7.5–7.8)                4.  Position the X-ray machine on the dorsal
      VetBooks.ir  1.  Stand the horse square with the cannon      5.  Focus–film distance: 100 cm.
                                                                      side of the limb.
                       bone vertical to the ground in each direc-
                       tion and ensure that all limbs are equally   6.  Use a horizontal X-ray beam.
                       weight-bearing.                             7.  Centre the X-ray beam at the level of the
                   2.  Place the plate in portrait orientation on the   metacarpus/metatarsus, midway between
                       palmar side of the leg, as close as possible   the fetlock and the carpus/tarsus.
                       to the limb.                                8.  Collimate around the area of interest.
                   3.  Place a R/L marker on the lateral side of the   9.  Exposure guide: 65 kVp, 10 mAs.
                       plate.






























































                   Figure 7.5   Positioning to obtain a DPa view of the metacarpus.