Page 91 - A Practical Guide to Equine Radiography
P. 91

72  A PRACTICAL GUIDE TO EQUINE RADIOGRAPHY



                   Dorsopalmar (DPa) (Figs 8.5–8.8)                4.  Position the X-ray machine on the dorsal
      VetBooks.ir  1.  Stand the horse square with the cannon      5.  Focus–film distance: 100 cm.
                                                                      side of the limb.
                       bone vertical to the ground in each direc-
                       tion and ensure that all limbs are equally   6.  Use a horizontal X-ray beam perpendicu-
                       weight-bearing.                                larly aligned to the leg and plate.
                   2.  Place the plate in portrait orientation on the   7.  Centre the X-ray beam to the level of the
                       palmar side of the joint as close as possible   mid carpal joint.
                       to the limb.                                8.  Collimate around the carpus, including the
                   3.  Place a R/L marker on the lateral side of the   proximal metacarpus.
                       plate.                                      9.  Exposure guide: 70 kVp, 10 mAs.

























































                   Figure 8.5  Positioning to obtain a DPa view of the carpus.



















       Equine Radiography.indb   72                                                                              27/11/2018   11:07