Modern equipment consists of two grounds, one of which is a “hot”
                   ground while the other is a “cold” ground. Hot ground is in the primary
                   side of a switch mode power supply while the cold ground is the
                   equipment ground.

                   Be careful when taking voltage measurements around these grounds. For
                   example, if you want to check the primary circuit of a power supply with
                   power on, always ground your meter or scope to the hot ground, while
                   check the secondary side using the cold ground.

                   If the “Hot” ground is not used and you use only the cold ground, the
                   voltage measurement might not be correct and it may destroy your meter.
                   One way to prevent this is to use an “isolation transformer”.