With power off, remove the transformer from the board and perform a
                   resistance or continuity test on primary and secondary winding as shown
                   on the picture of transformer below. If there is no resistance or ohms
                   reading on the primary and secondary winding measured, suspect an open
                   winding and the transformer need to be replaced. The advantage of this
                   method is you are safe because no power is applied to the transformer.

                   The disadvantage is checking the resistance for ohms reading is not as
                   accurate as when you perform a ringing test mentioned on the third
                   method. A shorted primary or secondary winding is still checked well
                   under resistance tests. However the good news is when either the primary

                   or secondary winding developed a short circuit, it will usually produced a
                   bad smell and the transformer gets very hot on its core or casing.