Page 36 - Encardio-Rite Consolidated Catalog - English
P. 36

I ENVIRONMENTAL MONITORING
        SOLUTIONS






          Automatic water level monitoring

                                     Model EWLR-101 automatic water level monitoring system provides significant quantitative
                                     data on the magnitude of water column, water level, temperature in single boreholes or
                                     multiple  boreholes  using  a  pressure  sensor.  Various  system  configurable  options  with
                                     telemetry  (GSM/GPRS  inbuilt  modem),  bluetooth  and  RF  communication  are  available
                                     depending upon the requirement and site conditions.
                                     The  datalogger  of  EWLR-101  system  is  programmed  to  automatically  store  the  water
                                     head/pressure at fixed intervals settable from once 5 seconds to every 168 hours with different
                                     options to download data. Data can be remotely transmitted at scheduled times with telemetry
                                     or downloaded on a laptop/mobile in field through Bluetooth or cable. The water level data
                                     can be corrected for specific gravity variations in water.

                                               Specifications
                                               Input                   EPP-30V, EPP-40V, EPP-60V pressure sensor
                                               Sensor Range (MPa)        EPP-30V: 0.2, 0.35, 0.5, 0.7, 1.0, 1.5, 2.0, 3.5,
                                                                       (20, 35, 50, 70, 100, 150, 200, 350 m WC)
                                                                       EPP-40V: 0.35, 0.5, 0.7, 1.0, 2.0 (35, 50, 70,
                                                                       100, 200 m WC)
                                                                       EPP-60V: 0.10, 0.20 (10, 20 m WC)
                                               Sensor Accuracy           ± 0.2 % fs standard
                                                                       ± 0.1 % fs optional
                                               Cable                     CS-1102 or CS-1302 four conductor
                                               Data logger            ESCL-10VT/ESDL-30
                                               Logger Memory capacity    8 MB Flash RAM, can store 3,145,728 data points
                                               Communication port       One RS-232 serial port
                                               Measuring modes          Linear or event sampling
                                               Power Supply             Lithium cells, Battery life is more than 5 years for
                                                                      4 measurement/day and one transmission/day.
                                               Bluetooth port           Detachable dongle
                                               *For more details please refer to datasheet # 1216.



          Automatic water quality monitoring

                                     Encardio-rite automatic water quality monitoring system offers a range of sensors that monitor
                                     various water quality parameters. Any combination of sensors can be used depending on
                                     application, precise monitoring need, measurement location or type of industry.
                                     Range of sensors offered includes:
                                          u Spectrophotometric sensor that measures
                                            u COD – Chemical Oxygen Demand
                                            u BOD – Biochemical Oxygen Demand
                                            u NO2-N – Nitrite
                                            u NO3-N – Nitrate
                                          u Dissolved Oxygen sensor
                                          u pH/ORPsensor
                                          u Conductivity sensor
                                          u Turbidity sensor
                                          u Oil in water analyzer
                                          u NH4 – Ammonium sensor
                                     The digital technology of these sensors can store calibration values directly in the sensor. This
                                     feature allows the user to calibrate the sensor in the laboratory and then return it to its location
                                     of use.
                                     The data analyzer is housed in a powder coated weather resistant sealable steel box that also
                                     contains a GSM/GPRS cellular phone network modem for transmission of data to a remote
                                     server. The data analyzer can be supplied with or without a large local LED display panel which
                                     can show the currently measured parameter values. The data analyzer can be powered by a
                                     12V battery backed mains or solar power supply as a factory configured option.
                                     For more detail, please refer to datasheet # 1401.