Floor Restriction by  The system can control the floor entry by giving key switch to authorized person.   OPTION
             Key Switch
             Priority call in car or  When the LOP or COP operated with VIP key switch, then elevator directly respond VIP call  OPTION
             Landing with Key   by passing the other call.
             switch
             Automatic startup  The system automatically implements startup torque compensation based on the current   STD
             torque           car load, achieving smooth startup and improving the riding comfort.
             compensation
             2 way- Intercom   An intercom system between the elevator and the master unit (in the supervisory panel,   STD
             System           etc.) is provided for emergency communication purposes.

             FRD -Phase 1     After receiving a fire emergency signal, the elevator does not respond to any call but   STD
                              directly runs to the fire emergency floor and waits.

                              After the elevator enters the firefighter running mode, door open/close is implemented by  STD
                              the jog operation (optional) by using the door open and close buttons rather than
             FRD – Phase 2    automatically. In addition, the elevator responds to only car calls and only one call can be
                              registered once.
                              In automatic running state, when the elevator lock switch acts or the set elevator time is   STD
                              reached, the elevator cancels all registered calls, returns to the elevator lock floor, stops
             Elevator lock    running, and turns off the lamp and fan in the car.
                              The system detects the running state of the elevator in real time. If the elevator speed   STD
             Runaway prevention exceeds the limit, the system immediately stops running of the elevator.
                              The system automatically judges the number of passengers in the car and compares it with  OPTION
                              the number of registered car calls. If there are excessive car calls, the system determines
             Anti-nuisance    that it is nuisance and cancels all car calls. In this case, passengers need to register correct
             function         car calls again.
             Full load By-pass   If the elevator is fully loaded, this operation will not respond to any hall calls and will only   OPTION
                              respond to the car calls.

             Car Emergency light  Emergency light in the car will start whenever there is power cut      STD


             Alarm Bell       In case of emergency, the alarm bell will be activated by pressing the alarm button in COP  STD
             OLD – Over Load   When the load of the car exceeds the rated capacity, Overload buzzer triggered and   OPTION
             Device           message displayed in COP display. This operation opens the car door, will remain open until
                              load get reduce.
             Interface for    The system provides an interface for intelligent residential management to perform remote  OPTION
             intelligent      monitoring on the state of elevators in the residential district.
             residential
               management                                                                                OPTION
             Car energy-saving-  If there is no running command within the set time, the system automatically cuts off the
             Auto Cut off     power supply to the lamp and fan in the car.
                              In automatic running state, when the elevator speed is smaller than 0.2 m/s at normal stop  OPTION
             Door pre-open    and the door zone signal is active, the system shorts the door lock by means of the shorting
                              door lock circuit contactor and outputs the door open signal, implementing door pre- open.
                              This improves the elevator use efficiency.

                              After landing at a floor, the elevator may move upward                     OPTION
             Micro-levelling   or downward due to the load change and the car door
                              is not aligned with the ground, which is inconvenient for in and out of passengers and
                              goods. In this case, the system allows the elevator to run to the levelling position in the
                              door open state at the leveling speed.
             Automatic Rescue  For the elevator configured with UPS, the system uses the UPS to implement low-speed   OPTION
             Device -ARD      self-rescue in the case of power failure.