SPECIFICATIONS:



                      Interior Volume           2083 Cubic Inches


                     Operating Voltage          11.6 to 15.0 Volts DC Standard plus
                                                100-240 Volts AC, 50-60 Hz with Tri-Voltage Option.
                                                4 Amps @ 12 Volts with Compressor Running
                                                Long term average approx. 1.3 Amps @ 12 Volts with

                     Operating Current          interior temp 40  F and exterior temp of 80 F
                                                Note: Average current draw is a function of temperature
                                                and quality of the insulation used in the cabinet.

                                                Electronic control system with auto power transfer.
                     System                     Hermetically sealed variable speed compressor and
                                                50 watt internal heater. Brushless D.C. fan.

                                                Control panel comes with 5 feet of wire.
                      Control Panel             Can be extended up to 20' with ordinary
                                                3 conductor thermostat wire.


                     Set Point Range            35 to 80 F
                     Weight (approx.)           44 lbs
                                               Drawer Cabinet      17" W x 9.8" H x 20" D
                     Dimensions                Compressor Unit     17" W x 9.8" H x 6" D



                      DIMENSIONS:
                      E-DRAWER                                                    DIMENSIONS:
                                                                                  CONTROL PANEL
                                            Front
                                          17 1/4 "


                                9.8"                                                       40



                                                                                     4.8"  O F /C  SET TEMP

                                           22"                                           ON
                                                            6 3/4"                           ALERT
                                                                                             HEATING
                                                                                         OFF
                                                                                             COOLING
                                                                                             DEFROSTING
                                                                                         ENVIRONMENTAL CABINET
                                                                                           2.4"
                                           Side
                                 Compressor cannot be moved
   56   57   58   59   60   61   62   63   64   65   66