Speci cation





               Mechanical construction                          Management control
               • Sheet stainless steel frame.                   • Expandable product code support (500 fitted as standard).
               • High care feet.                                • Selectable weighing regime (minimum, emark, mean
               • Sealed for life bearings.                       weight tracking).
               • High accuracy, high speed, single point, analogue Loadcell.  • ‘Use Case’ configurable security access. Access levels
                                                                 for operators, engineers, supervisors and Quality
               Reject integrity                                  Assurance (QA).
               • Servo driven.                                  • Self diagnostic ability to maintain the highest levels
               • Gating sensor.                                  of performance.
               • Time out control / Pack-track software.        • Trend feedback to filler to minimise product giveaway.
               • Reject confirmation.                            • Performance alerts emailed in real time.
               • Bin full indication.
               • Lockable reject collection mechanisms.         QA system support
               • Electronic ‘Reject Mechanism in Place’ monitor.  • Easy to use graphical display to support Reject Integrity
               • Electronic ‘Reject Mechanism Locked’ monitor.   compliance tests.
               • Reject check sensor.                           • Reject Integrity compliance tests logged and available
               • Interlocked top covers.                         for download.
               • ‘Last for Life’ stainless steel top covers throughout.  • Comprehensive Statistics Set (Audit) generated and
               • A three beacon light stack with a stainless steel  stored for download.
                protective cage.                                • Statistics download configurable by time, product code
                                                                 or on demand.
               Single point operator interface                  • Statistics output by eternal IP65 USB, ethernet or by email.
               • 15.1” menu driven Thin Film Transistor (TFT) full colour  • QA alerts emailed in real time.
                display with drag and drop functionality.
               • Display resolution: 1:12,000.                  Line integration
                                                                • Sleep mode fitted to reduce energy consumption.
               Electronic control system                        • Configurable Inputs and Outputs (IO).
               • Industrial standard components and manufacturing  • Level D safety circuit resulting in Programmable Logic
                processes for ‘full-life’ machine support.       devices (PLd) which are above industry standard.
               • Logical, colour coded Printed Circuit Board (PCB) design
                reduces customer engineer training and support.  Management information 
                                                                As standard, statistical data is available to be sent, on
               Machine operation features                       demand, to your network for storage and later use. 
               • Menu driven from single operator interface.    In addition to being able to be connect to your network, the
               • Fully integrated product codes mean settings for all
                                                                system is also fitted with the USBStore data capture system,
                inspection processes (weight, metal) are automatically
                                                                which is a simple yet highly effective way in which to manage
                adjusted on selection of each product code.
               • Customisable graphical interface reduces training time   this data. The system collects and manages the statistical
                                                                data and results generated for all measured attributes at the
                and increases operational awareness.
                                                                inspection and weight stations. As with the network
                                                                communications the data is identified by the date and time
                                                                they are generated and the statistical data file can then be
                                                                saved to a memory stick, networked to a computer or
                                                                emailed.








                                           Fully integrated metal detector control
                                           operated from main touchscreen.















   Positive, accurate, servo driven reject                                        Weighing area design reduces damage
   mechanism eliminates compressed air.                                           risk, improves access and performance.