Page 3084 - Flipbook_SolidDesignSoutheast2020
P. 3084
69 William Street, Belleville, NJ 07109
PH: 973-759-4600 * Fax: 973-759-6449
EMAIL: info@vac-u-max.com
WEB SITE: www.vac-u-max.com
Cleaning
Most A270-BPE high purity tubing is available from stock with ID cleaned for oxygen service. Other ID
cleaning procedures are available including thermocouple cleaning per ASTM A632 or Nitric Acid &
deionized water rinse. The de-ionized water system guarantees less than 50 ppb TOC with an average
of 10 ppb and a resistivity up to 18 M. They also utilize 99.9999% pure Nitrogen which is filtered to 0.003
µm at the point of use. Cleaning and packaging are performed in a certified Class 100 Cleanroom.
Surface Finish
Surface finish is 20 µ-in Ra (0.5 µm) ID maximum, 30 µ-in Ra (0.8 µm) OD maximum measured per
ASME/ANSI B46.1 with the profilometer reading at 90 degrees to major polishing pattern.
Packaging
As a final step in maintaining purity standards following cleaning, our A270-BPE tubing is packaged
using protective 6 mil poly sleeving along with air tight plastic end caps. The tubing is then placed in
wood boxes for maximum protection during shipment. Other packaging is available on customer request.
Dimensional Tolerances
all dimensions in inches
SIZE OD NOMINAL WALL OUTSIDE LENGTH WALL
INCHES INCHES DIAMETER INCHES
1.5 .065 (1.65) +/-. 0O8 (.20) +1/8 (3.18) - 0 +/-10.0%
2.0 .065 (1.65) +/- .008(.20) +1/8 (3.18) - 0 +/-10.0%
2.5 .065 (1.65) +/- .010(.25) +1/8 (3.18) - 0 +/-10.0%
3.0 .065 (1.65) +/- .010(.25) +1/8 (3.18) - 0 +/-10.0%
4.0 .083 (2.11) +- .015 (.38) +1/8 (3.18) - 0 +/-10.0%