Page 723 - Flipbook_SolidDesignSoutheast2020
P. 723
Fill Types & Appilications
Bulk & Dribble Setpoint Volumetric
Specifies filling & weighing in a two-stage fill Specifies filling & weighing in a single stage fill Specifies filling only. No weighing occurs.
cycle where the greater portion of product is where product is dispensed as it approaches Product is dispensed for a user-specified
dispensed, weighed, then filled again to a de- a user-defined target weight. Product weighed number of auger revolutions. Bypasses load-
sired target weight. After the second, dribble, at the end of filled and categorized as “Ac- cell in cases of failure/malfunction.
fill, the container is weighed again and catego- ceptable”, “Underweight”, or “Overweight.”
rized as “Acceptable”, “Underweight”, or Applications — Moderate Accuracy, depending
“Overweight.” Applications — Moderate Accuracy/Moderate on product density. High production rates. Al-
Production Rates (higher than Bulk & Drib- lows production to continue with loadcell
Applications — High Accuracy, Low Produc- ble). Used with product that changes density. failures or malfunctions.
tion Rates, Consistent Product Density
Setpoint Fill Parameters Volumetric Parameters
Bulk & Dribble Parameters ● Fill Type (Setpoint Fill) ● Fill Type (Volumetric)
● Fill Type (Bulk and Dribble) ● Target Weight ● Auger Revolutions
● Target Weight ● Low & High Tolerance ● Delay After Fill
● Low & High Tolerance ● Bulk Auger Revolutions
● Set Bulk Percent ● Preact Weight
● Initial Auger Revolutions ● Read Final Weight
● Maximum Auger Revolutions ● Maximum Fill Time
● Fill Delay ● Auto. Tare Rate
● Auto. Tare Rate ● Scale Tare Delay
● Scale Tare Delay ● Delay After Bulk
● Delay After Bulk ● Final Weigh Delay
● Final Weigh Delay