Page 723 - Flipbook_SolidDesignSoutheast2020
P. 723

Fill Types & Appilications



      Bulk & Dribble                          Setpoint                               Volumetric


      Specifies filling & weighing in a two-stage fill  Specifies filling & weighing in a single stage fill  Specifies filling only. No weighing occurs.
      cycle where the greater portion of product is  where product is dispensed as it approaches  Product is dispensed for a user-specified
      dispensed, weighed, then filled again to a de-  a user-defined target weight. Product weighed  number of auger revolutions. Bypasses load-
      sired target weight. After the second, dribble,  at the end of filled and categorized as “Ac-  cell in cases of failure/malfunction.
      fill, the container is weighed again and catego-  ceptable”, “Underweight”, or “Overweight.”
      rized as “Acceptable”, “Underweight”, or                                       Applications — Moderate Accuracy, depending
      “Overweight.”                           Applications — Moderate Accuracy/Moderate  on product density. High production rates. Al-
                                              Production Rates (higher than Bulk & Drib-  lows production to continue with loadcell
      Applications — High Accuracy, Low Produc-  ble). Used with product that changes density.  failures or malfunctions.
      tion Rates, Consistent Product Density
                                              Setpoint Fill Parameters               Volumetric Parameters
      Bulk & Dribble Parameters                 ● Fill Type (Setpoint Fill)            ● Fill Type (Volumetric)
        ● Fill Type (Bulk and Dribble)          ● Target Weight                        ● Auger Revolutions
        ● Target Weight                         ● Low & High Tolerance                 ● Delay After Fill
        ● Low & High Tolerance                  ● Bulk Auger Revolutions
        ● Set Bulk Percent                      ● Preact Weight
        ● Initial Auger Revolutions             ● Read Final Weight
        ● Maximum Auger Revolutions             ● Maximum Fill Time
        ● Fill Delay                            ● Auto. Tare Rate
        ● Auto. Tare Rate                       ● Scale Tare Delay
        ● Scale Tare Delay                      ● Delay After Bulk
        ● Delay After Bulk                      ● Final Weigh Delay
        ● Final Weigh Delay