measurement devices
  EXAM ROOM NEEDS
PockEt cff tEstERTM CSCFF $429.95
The critical flicker frequency testing device is a compact, hand-held device for determining the CFF values of a patient’s vision. Critical fusion frequency is the point at which a light is
      Placido disk, cliP, & haNdlE This economical keratoscope is used to determine the curvature
characteristics of the anterior surface of the cornea.
BC2171 $44.95 Round cornered 10.5” x 11” disc with two sided print.
White vinyl washable.
Order Now by Phone at (574) 259-2070 or Go To www.bernell.com 24
   Backside of card with lens clip
   Includes: Handle and trial lens holder.
accommodatioN coNVERgENcE RulE
Used to test & train monocular, binocular, accommodation, and rock. Trains convergence using physiological diplopia as the control on suppression. Features four scales; dioptric values, duane age, centimeters and inches. Made of durable plastic with engraved black numbers.
  GR50 (Complete Kit) GR50CH (Cardholder Only) BC21 (Replacement Card)
$79.95 $19.95 $2.50
    Size: 21” long x 7/16” square
  ExoPhthalmomEtER
Made of clear plastic, exophthalmometer has millimeter scale on both sides to check for parallax. Luedde design.
3-1/4” long. Fits in coat/shirt pocket.
 WO05655 $39.95
  Kit Includes: Accommodation convergence rule, slide card holder and two cards.
  ASSESSMENTS
 The CFF unit will give you three values:
1) The point where the solid light first starts to flicker is referred to as non-seeing to seeing or NSTS. 2) The point where you are seeing the flicker and the frequency increases till you no longer
see the flicker, which is referred to as seeing to non-seeing or STNS. 3) The average of the two values above.
 Raf (Royal aiR foRcE RulE) coNVERgENcE RulE
RAF Rule (Royal Air Force Rule) provides a binocular gauge to measure Objective and Subjective Convergence as well as Accommodation in 1 mm increments. The RAF Rule
consists of a 50 cm long rule with a slider holding a
rotating four-sided cube.
RAFCR1 $389.95
Each side has a different target. The first has a vertical line with a central dot for convergence fixation. The others provide a limited number of lines of near reading examples.
  accommodatioN & NEaR PoiNt RulE
Dark Grey
The near point rule is the point closest to the bridge of the nose where convergence and binocular single vision can no longer be maintained as an object approaches.
 GR50B $84.95
 OPTICAL
Kit Includes:
• Accommodation Convergence Rule • Two Cards printed on Styrene
• Slide Card Holder
Front Back
  VISION THERAPY
Made of gray opaque plastic with white markings.
The Accommodation and Near Point Rule measures 50 cm long, 10 mm square, it is engraved with Centimeters, Inches, Diopter Scales and Duane Age (the mean of the near point of accommodation at different ages according to
Duane Age) with sliding cardholder.
 NEURO REHABILITATION
 LOW VISION
 REFERENCE
     flickering so fast that the visual system perceives it as a solid or non-flickering light.
In certain neurological conditions, the CFF of a patient will change. The measurements may be taken on the right eye, left eye or both eyes.
Scan QR code to view an animation of the flickering light.
   