C1 FLEXILINE C1- 48 Flexible hoses
data sheet index
Installation instruction for hoses
Wrong Right
Esempio 5: il raggio di curva è troppo Use a pulley of proper diameter.
piccolo.
Example 6: cyclic flexural strain and too A rank torsional strain can be avoided with
small bending radius behind fittings. the use of two elbows.
Example 7: torsional strain caused by No torsional strain due to the use of stiff
misalignment compound
between hose axis and direction of motion. elbows.
Example 8: detrimental cyclic motion with With the help of a live pulley, cyclic motion
flexural strain. and torsion ere eliminated. To avoid sagging,
a support may be necessary.
Example 9: torsional strain and too high Hose twist and bends are eliminated with the
flexural load on the directly behind the left use of stiff elbows.
fitting.
Example 10: The hose twists on tightening. Twist is avoided by holding sockets firmly
during tightening.
Example 11: Hose coil should not be Unwound hose as shown in the sketch.
unwound by simply pulling it at one end,
since this will induce a twist.
48
diflon.it