                              7.7.5.2.4     Ventilation (33)
                                            Slots for supply ventilation over the void space (plenum) are not
                                            allowed directly over FOOD preparation areas, FOOD STORAGE
                                            areas, or clean EQUIPMENT storage.


                                            This section applies to vessels built or renovated in accordance
                                            with the 2011 VSP Construction Guidelines or later.

                       7.7.6   Lighting
                               This section applies to self-service and served candy shops where employees
                               serve candy and refill self-service containers and CONSUMERS serve
                               themselves.


                          7.7.6.1    Intensity

                              7.7.6.1.1     220 Lux/20 Foot Candles (36)
                                            The light intensity must be at least 220 lux (20 foot candles) on
                                            FOOD preparation surfaces.

                                            The light intensity must be at least 220 lux (20 foot candles) as
                                            measured 75 centimeters (30 inches) above the deck in FOOD
                                            PREPARATION AREAS, handwashing facilities,
                                            WAREWASHING areas, EQUIPMENT, and UTENSIL storage,
                                            pantries, toilet rooms, and CONSUMER self-service areas.

                              7.7.6.1.2     110 Lux/10 Foot Candles (36)
                                            When lights are in use, the light intensity must be at least 110 lux
                                            (10 foot candles) at a distance of 75 centimeters (30 inches) above
                                            the deck in walk-in refrigerator units and DRY STORAGE
                                            AREAS and in other areas and rooms during cleaning operations.


                                            The light intensity must be at least 110 lux (10 foot candles)
                                            behind and around mounted EQUIPMENT, including counter-
                                            mounted EQUIPMENT.


                              7.7.6.1.3     Bars and Waiter Stations (36)
                                            The light intensity must be at least 110 lux (10 foot candles) at
                                            handwashing stations in bars. In bars and dining room waiter
                                            stations, provide 220 lux (20 foot candles) light intensity during
                                            cleaning operations.

                          7.7.6.2    Protected

                              7.7.6.2.1     Shielded/Shatter Resistant (36)
                                            Light bulbs must be shielded, coated, or otherwise shatter resistant
                                            in areas with exposed FOOD; clean EQUIPMENT, UTENSILS,