                                         2. Add clean water to the clear container, cover, and shake.
                                         3. Allow the container to rest undisturbed for 30 minutes.
                                         4. Evaluate sample. If, after 30 minutes of settling, a measurable
                                            layer of sediment is within or on top of the filter media or fine,
                                            colored particles are suspended in the water, the organic
                                            loading may be excessive. Consider media replacement.
                                         5. Record results of filter inspection and sedimentation test in a
                                            log.

                                     Cartridge filters must be replaced based on inspection results or
                                     manufacturer’s recommendations, whichever is sooner.


                                     The granular filter media must be replaced at least every 6 months. Before
                                     the new filter media is placed in the filter housing, the housing must be
                                     scrubbed with an appropriate cleanser, rinsed, and disinfected.
                                     DISINFECTION must be accomplished with an appropriate HALOGEN-
                                     based DISINFECTANT at 1 ppm for 50 minutes, or an equivalent CT
                                     VALUE. Record the filter replacement date and cleaning and
                                     DISINFECTION of the filter housing in a log. The log must include the
                                     DISINFECTANT residual and contact time or CT VALUE.

                                     Filter pressure gauges and valves must be replaced when they are
                                     defective.

                                     The operating manuals for all components such as filters, pumps,
                                     HALOGEN and pH control EQUIPMENT, and UV DISINFECTION
                                     systems must be maintained aboard the vessel in a location ACCESSIBLE
                                     to crew members who are responsible for the operation and maintenance
                                     of these facilities.

                          13.8.3.5  Halogen and pH Control
                                     Automated HALOGEN dosing and pH control systems must be installed
                                     and maintained.


                                     Halogenation must be by use of chlorine or bromine. A free residual of
                                     HALOGEN must be maintained between 3.0-10.0 ppm for chlorine and
                                     4.0-10.0 ppm for bromine.

                                     The pH levels must be maintained between 7.2 and 7.6.


                          13.8.3.6  UV Disinfection
                                     A UV DISINFECTION system must be installed after filtration and before
                                     HALOGEN-based DISINFECTION.

                                     The UV DISINFECTION system must be maintained at an intensity that
                                     inactivates Cryptosporidium parvum and Giardia.