                       5.3.3   Potable Water Hoses

                          5.3.3.1    Construction

                              5.3.3.1.1     Fittings (08)
                                            POTABLE WATER hoses must have unique fittings from all other
                                            hose fittings on the vessel.

                              5.3.3.1.2     Identification (08)
                                            POTABLE WATER hoses must be labeled for use with the words
                                            “POTABLE WATER ONLY” in letters at least 13 millimeters
                                            (0.5 inch) high at each connecting end.

                              5.3.3.1.3     Construction (08)
                                            All hoses, fittings, and water filters used in the bunkering of
                                            POTABLE WATER must be constructed of safe, EASILY
                                            CLEANABLE materials APPROVED for POTABLE WATER use
                                            and must be maintained in good repair.


                              5.3.3.1.4     Other Equipment (08)
                                            Other EQUIPMENT and tools used in the bunkering of POTABLE
                                            WATER must be constructed of safe, EASILY CLEANABLE
                                            materials, dedicated solely for POTABLE WATER use, and
                                            maintained in good repair.

                              5.3.3.1.5     Locker Construction (08)
                                            POTABLE WATER hose lockers must be constructed of
                                            SMOOTH, nontoxic, corrosion resistant, EASILY CLEANABLE
                                            material and must be maintained in good repair.

                              5.3.3.1.6     Locker Identification (08)
                                            POTABLE WATER hose lockers must be labeled “POTABLE
                                            WATER HOSE AND FITTING STORAGE” in letters at least
                                            13 millimeters (0.5 inch) high.


                              5.3.3.1.7     Locker Height (08)
                                            POTABLE WATER hose lockers must be mounted at least
                                            460 millimeters (18 inches) above the deck and must be self-
                                            draining.

                              5.3.3.1.8     Locker Closed (08)
                                            Locker doors must be closed when not in use.