Page 2 - FQ10498.GibsonsEnergyPartnership.Trimac.Mississauga.DC10000
P. 2
Gibson’s Energy Partnership Proposal No. Q10498
440 2 Avenue S.W., Suite 1700
nd
Calgary, Alberta Date: May 9, 2017
CANADA T2P 5E9
Salesman: GET/kr
Attention: Mr. Mike Johnson
Tel: 780-392-6652
E-mail: mike.johnson@gibsons.com Cell: 780-920-0827
Fax: 780-392-6723
Subject: Duplicate of TRIMAC in MISSISSAUGA,
ONTARIO, CANADA, Serial No. J05491
We are pleased to quote the following, Model DC 10,000 DIRECT CONTACT WATER
HEATER to be installed by the purchaser. This system is designed on the basis of the
information supplied to us by your plant to handle the following approximate quantities and
temperatures and produce the stated results.
CUSTOMER REQUIREMENTS:
Hot Water -------------------------------------------- 9,600 GPH (160 GPM @ 140 Deg. F.)
Cold Water -------------------------------------------------------------------------- 60 Deg. F.
Gas Pressure --------------------------------------------------------- 5 PSIG @ 10,000 FT /HR.
3
NOTE: All figures are in U. S. Units of Measurement.
HEATER CAPACITY:
Direct Contact Water Heater (Patent No. 4574775) is rated at 10,000,000 BTU/HR and is capable
of heating 160 GPM from 35 to 160 Deg. F.
ESTIMATED ANNUAL VALUE OF HEAT LOAD REDUCTION:
Based upon heating 9,600 GPH of water from 60 to 140 Deg. F., 40 hours per week for 52 weeks
per year, and natural gas at a cost of $6.00 per 1,000 CU FT., the annual cost reduction would be
$34,230.00 when compared to a conventional gas-fired heater or boiler system operating at 70%
system efficiency.
INSTALLATION OPTION:
In addition to the following standard equipment, an OPTIONAL Pump, Valve, and Piping
Package is available to substantially reduce set-up time and installation.
LUDELL EXTENDED WARRANTEE:
Ludell warrants its water heaters against defects in material and workmanship, under normal use and
service for a period of five (5) years after shipment for the fabricated stainless steel shell and one (1) year
for all other components. Ludell's obligation is limited to repair or replacement f.o.b. Ludell's plant.
Please note that customer supplied water chemistry may adversely affect the equipment materials of
construction. If the water supply is aggressive, acidic or high in chlorides a higher-grade stainless steel
alloy must be utilized. Contact Ludell for a quote revision if your supply water chemistry is of poor
quality.