Page 127 - Corkjoint E-Catalogue
P. 127
AREAS OF APPLICATION
For expansion & construction joints in concrete
Slab on ground and roof slab joints
Connection of slab to wall (podium deck area) locations
Concrete pathways or walkways
Carparks, driveways, tunnels and concrete roads
Reservoirs, dams, water treatment plants & sewage treatment plants
Note : The product’s design and performance, its intended use, installation and final confirmation and approval for
use, must be provided by the project’s Design Engineer and Project Manager.
PHYSICAL PROPERTIES
PROPERTY TEST METHOD RESULT
Tensile strength MPA BA 903: Part A2: 1995 12.9
Elongation at Break, % BA 903: Part A2: 1995 320
Hardness, IRHD BA 903: Part A26: 1995 78
Density, g/cm BA 903: Part A1: 1996 1.41
Loss of Mass after 7 days / 80ºC*, % LGm in-house method 0
Immersion in Distilled Water, 24h / 23ºC MS ISO 1817: 2002 0
Volume Change, %
PRODUCT DIMENSIONS
34.00
23.00
6.00
5.00
22.00
30.00
26.50 13.00
4.00
4.00
10.00
10.00
16.50 19.00 4.00
3.50
J-SEAL 612 J-SEAL 620
®
®
TYPICAL APPLICATIONS
J-Seal ® J-Seal ®
Expansion Joint Fillerboard
Expansion Joint Fillerboard
1st Pour 2nd Pour 1st Pour 2nd Pour
Lean Concrete Lean Concrete
SLAB ON GROUND (EXPANSION JOINT) SLAB ON GROUND (CONSTRUCTION JOINT)
Note : Contact CORKJOINT for custom application requirements.
info@corkjoint.com | corkjoint.com Page 2