Page 154 - Parker - Hydraulic and Lube Filtration Products
P. 154
100P Series
Element Performance
Flow/Pressure Drop Data
Fluid Conditions: Viscosity 140 SSU and Sp. Gr. 0.88
20 200
HOUSING
HOUSING BYP
BYPASS VALVEASS VALVE
15 150
ΔP IN PSI 10 ΔP IN PSI 100
“S“ AND “F” PORT
“S“ AND “F” PORT 50
“H“ AND “T” PORT
“H“ AND “T” PORT
5
0
0 0 55 110 165 220 275
0 55 110 165 220 275
FLOW RATE IN GPM
1050-H-210
1070-Z-220
Length 2
25
1050-H-2FF
1070-Z-221
40 REVERSE Length 2
35 FLOW VALVE 20 1050-H-2FF 1050-H-210 1070-Z-220 1070-Z-221
1070-Z-222
1070-Z-222
ΔP IN PSI 20 Additive P in reverse ΔP IN PSI 15 1070-Z-223
Δ
30
flow direction
1070-Z-223
25
15
Δ
Additive P, normal
10 10
flow direction
5 5
0
0 55 110 165 220 275
0
0 55 110 165 220 275
FLOW RATE IN GPM
FLOW RATE IN GPM
Multipass Test Results to ISO 4572 (Time Weighted Average)
Filtration Rating
Media Code x > 100 3 6 10 12 20 25
02Q 3 >100 >300 >1500 >2000 >5000 INF
99.0 99.67 99.93 99.95 99.98
05Q 6 12 >100 >1000 >2000 >5000 INF
91.7 99.0 99.9 99.95 99.98
10Q 10 8 22 >100 >200 >5000 INF
87.5 95.4 99.0 99.5 99.98
20Q 20 – 2 8 20 >100 >200
50.0 87.5 95.0 99.0 99.5
Element Beta ratio x
Element effi ciency in percent*
149