Page 18 - Parker - Hydraulic and Lube Filtration Products
P. 18

PT Series


               PT2-1 Element Performance




                                 Efficiency                                       Capacity
                Beta Rating                        Efficiency  %  PSID                                BAR
                10000                                             100

                                                                                                         6
                         2Q       5Q
                                                                   80
                                                                                      5Q
                 1000                                    99.9                         2Q                 5
                                         10Q                                          10Q
                                                                                      20Q
                                                                   60                                    4
                  200                                    99.5
                                                                  s
                  100                                    99.0
                                                 20Q                                                     3
                                                                   40
                   20                                    95.0                                            2

                                                                   20
                                                                                                         1
                   2                                     50.0

                                                                    0                                    0
                     0     4      8     12    16     20               0   1   2    3   4    5    6   7
                                Micron Size (c)                                 Capacity grams


                         Flow  vs. Pressure Loss*
                                   LPM
                     0   10   20    30   40   50   60
                  25

                                                        1.5
                  20


                  15
                 PSID                                   1.0 BAR
                  10

                                                        0.5
                   5



                   0                                    0.0
                     0        5          10        15

                                   GPM

               Results typical from Multi-pass tests run per test standard ISO 16889 @ 10 gpm to 100 psid terminal - 10 mg/L BUGL.
               Refer to Appendix on pages 264-265 for relationship to test standard ISO 4572.


           *Note: Pressure drop calculations are based on SAE-12 porting.

                                                             13